{"id":6049,"date":"2020-07-30T16:55:54","date_gmt":"2020-07-30T14:55:54","guid":{"rendered":"http:\/\/neu.ski-consult.de\/?page_id=6049"},"modified":"2023-11-16T15:15:43","modified_gmt":"2023-11-16T14:15:43","slug":"onshore-windenergieanlagen","status":"publish","type":"page","link":"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/","title":{"rendered":"Onshore-Windenergie"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"6049\" class=\"elementor elementor-6049\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3916276 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3916276\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-aaa3f90\" data-id=\"aaa3f90\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2cbe442 elementor-widget elementor-widget-heading\" data-id=\"2cbe442\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Support and foundation structures for wind turbines<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-20be27d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"20be27d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c280aec\" data-id=\"c280aec\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3ca5146 elementor-widget elementor-widget-text-editor\" data-id=\"3ca5146\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The SKI engineering company engaged in supporting and establishing structures for onshore wind turbines. The offshore variants are found in\u00a0<a class=\"internal-link\" title=\"damage accumulation hypothesis\" href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/\">Offshore wind turbines<\/a>\u00a0under a separate heading.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5a5d423 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5a5d423\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-16 elementor-top-column elementor-element elementor-element-dc15e5a\" data-id=\"dc15e5a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ea1e5be elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"ea1e5be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/stahlrohrturm\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2023\/11\/AN-WEA-Stahlrohrturm.gif\" title=\"AN-WEA-Stahlrohrturm\" alt=\"WEA-Stahlrohrturm\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">WEA-Stahlrohrturm<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-16 elementor-top-column elementor-element elementor-element-7a3e572\" data-id=\"7a3e572\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3d1461d elementor-widget elementor-widget-image\" data-id=\"3d1461d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/hybridturm\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"142\" height=\"300\" src=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Hybridturm-Ventur-01-142x300.jpg\" class=\"attachment-medium size-medium wp-image-7401\" alt=\"\" srcset=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Hybridturm-Ventur-01-142x300.jpg 142w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Hybridturm-Ventur-01-486x1024.jpg 486w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Hybridturm-Ventur-01-768x1619.jpg 768w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Hybridturm-Ventur-01-728x1536.jpg 728w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Hybridturm-Ventur-01-971x2048.jpg 971w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Hybridturm-Ventur-01-6x12.jpg 6w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Hybridturm-Ventur-01-scaled.jpg 1214w\" sizes=\"(max-width: 142px) 100vw, 142px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Hybrid tower - concrete shaft \/ steel tube section<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-16 elementor-top-column elementor-element elementor-element-33ab956\" data-id=\"33ab956\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-481f6d7 elementor-widget elementor-widget-image\" data-id=\"481f6d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/gittermastturm\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"117\" height=\"300\" src=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/09\/WEA-Gittermaste-117x300.jpg\" class=\"attachment-medium size-medium wp-image-6755\" alt=\"\" srcset=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/09\/WEA-Gittermaste-117x300.jpg 117w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/09\/WEA-Gittermaste-399x1024.jpg 399w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/09\/WEA-Gittermaste-768x1970.jpg 768w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/09\/WEA-Gittermaste-599x1536.jpg 599w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/09\/WEA-Gittermaste-798x2048.jpg 798w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/09\/WEA-Gittermaste-scaled.jpg 998w\" sizes=\"(max-width: 117px) 100vw, 117px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Hybrid tower - Lattice tower \/ Steel tube section<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-16 elementor-top-column elementor-element elementor-element-ea20969\" data-id=\"ea20969\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-292a4d8 elementor-widget elementor-widget-image\" data-id=\"292a4d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"163\" height=\"300\" src=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Abgespannte-WEA-163x300.jpg\" class=\"attachment-medium size-medium wp-image-6924\" alt=\"\" srcset=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Abgespannte-WEA-163x300.jpg 163w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Abgespannte-WEA-556x1024.jpg 556w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Abgespannte-WEA-768x1413.jpg 768w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Abgespannte-WEA-835x1536.jpg 835w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Abgespannte-WEA-1113x2048.jpg 1113w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Abgespannte-WEA-7x12.jpg 7w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Abgespannte-WEA-scaled.jpg 1391w\" sizes=\"(max-width: 163px) 100vw, 163px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Guyed WT with tubular steel sections<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-16 elementor-top-column elementor-element elementor-element-2732253\" data-id=\"2732253\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-754ba21 elementor-widget elementor-widget-image\" data-id=\"754ba21\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/kleinwindenergieanlagen\/\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"107\" height=\"300\" src=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/09\/Hochbau-002-107x300.jpg\" class=\"attachment-medium size-medium wp-image-6702\" alt=\"\" srcset=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/09\/Hochbau-002-107x300.jpg 107w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/09\/Hochbau-002.jpg 287w\" sizes=\"(max-width: 107px) 100vw, 107px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Tilt-Up Tower<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-16 elementor-top-column elementor-element elementor-element-9c28edc\" data-id=\"9c28edc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-688fcc5 elementor-widget elementor-widget-image\" data-id=\"688fcc5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/gittermastturm\/\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"129\" height=\"300\" src=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Gittermast-WEA-129x300.jpg\" class=\"attachment-medium size-medium wp-image-6925\" alt=\"\" srcset=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Gittermast-WEA-129x300.jpg 129w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Gittermast-WEA-439x1024.jpg 439w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Gittermast-WEA-768x1791.jpg 768w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Gittermast-WEA-659x1536.jpg 659w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Gittermast-WEA-878x2048.jpg 878w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Gittermast-WEA-5x12.jpg 5w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/Gittermast-WEA-scaled.jpg 1098w\" sizes=\"(max-width: 129px) 100vw, 129px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">WTG - lattice mast<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6628f45 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6628f45\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-150b925\" data-id=\"150b925\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5558e2d elementor-widget elementor-widget-text-editor\" data-id=\"5558e2d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The range of services includes static and dynamic structural analysis using numerical simulation tools for the following applications:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b6c3ff8 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b6c3ff8\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-7049fe9\" data-id=\"7049fe9\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-08ab7f9 elementor-widget elementor-widget-wp-widget-nav_menu\" data-id=\"08ab7f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"wp-widget-nav_menu.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5>Onshore-Windenergie<\/h5><div class=\"menu-onshore-windenergie-container\"><ul id=\"menu-onshore-windenergie\" class=\"menu\"><li id=\"menu-item-8381\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8381\"><a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/flach-und-tiefgruendung\/\">Shallow and deep foundations<\/a><\/li>\n<li id=\"menu-item-8376\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8376\"><a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/gittermastturm\/\">Lattice mast towers<\/a><\/li>\n<li id=\"menu-item-8375\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8375\"><a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/hybridturm\/\">Hybrid tower<\/a><\/li>\n<li id=\"menu-item-8380\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8380\"><a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/kleinwindenergieanlagen\/\">Small wind energy systems<\/a><\/li>\n<li id=\"menu-item-8768\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8768\"><a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/\">Onshore-Windenergie<\/a><\/li>\n<li id=\"menu-item-8377\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8377\"><a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/rotorblatt\/\">Rotor blade<\/a><\/li>\n<li id=\"menu-item-8379\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8379\"><a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/sandwichturm\/\">Sandwich tower<\/a><\/li>\n<li id=\"menu-item-8371\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8371\"><a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/stahlrohrturm\/\">Tubular steel tower<\/a><\/li>\n<li id=\"menu-item-8378\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8378\"><a href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/weiterbetrieb-von-wea\/\">Continued operation of wind turbines<\/a><\/li>\n<\/ul><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-fa82313\" data-id=\"fa82313\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8d73a4c elementor-widget elementor-widget-image\" data-id=\"8d73a4c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"575\" src=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/DJI_0053-1024x575.jpg\" class=\"attachment-large size-large wp-image-7151\" alt=\"\" srcset=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/DJI_0053-1024x575.jpg 1024w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/DJI_0053-300x168.jpg 300w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/DJI_0053-768x431.jpg 768w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/DJI_0053-1536x863.jpg 1536w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/DJI_0053-2048x1150.jpg 2048w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/10\/DJI_0053-16x9.jpg 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Installation of a WT with hybrid tower<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-101ea5a\" data-id=\"101ea5a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9e2b72b elementor-widget elementor-widget-image\" data-id=\"9e2b72b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"450\" height=\"600\" src=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/07\/csm_WEA_Ansicht_04_576958ef67.jpg\" class=\"attachment-large size-large wp-image-6051\" alt=\"\" srcset=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/07\/csm_WEA_Ansicht_04_576958ef67.jpg 450w, https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/07\/csm_WEA_Ansicht_04_576958ef67-225x300.jpg 225w\" sizes=\"(max-width: 450px) 100vw, 450px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Steel tower with longitudinally oriented subshells\n<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f09d8d7 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f09d8d7\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a470526\" data-id=\"a470526\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-345b8cc elementor-widget elementor-widget-text-editor\" data-id=\"345b8cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In addition to the design of conventional support structures, we are also available for the development and realization of new structures. For special applications of our calculation tools please\u00a0<a title=\"damage accumulation hypothesis\" href=\"https:\/\/ski-consult.de\/en\/kontakt\/\">contact us<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9b425d1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9b425d1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-af490d5\" data-id=\"af490d5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d2ca919 elementor-widget elementor-widget-heading\" data-id=\"d2ca919\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">The development of the system size and power rating\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-420efb1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"420efb1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-ddab1b5\" data-id=\"ddab1b5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b065162 elementor-widget elementor-widget-text-editor\" data-id=\"b065162\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The continuous development of even larger turbines is closely linked to the increase of the dimensions of the support structures. In GASCH &amp; TWELE 2005 is a compilation of specific tower masses as a function of hub height to be found. The required tower masses rise according to the structural load in an approximately square with the hub height. For a prototype with 6 MW rated power production of the bottom tower section would be possible as pure tubular steel construction only with increased manufacturing and assembly costs, with the tower manufacturer come up against technical production limits in steel construction. For example, in most plants, the round rolls of heavy plates with a thickness up to 70 mm is not yet a limiting factor. During transportation to onshore locations, there are many road bridges because of limited vertical clearance of 4.3 m, a further restriction on the tower diameter.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-09c66ab\" data-id=\"09c66ab\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b1db04f elementor-widget elementor-widget-image\" data-id=\"b1db04f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"628\" src=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2021\/12\/Entwicklung-1024x628.jpg\" class=\"attachment-large size-large wp-image-8796\" alt=\"\" srcset=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2021\/12\/Entwicklung-1024x628.jpg 1024w, https:\/\/ski-consult.de\/wp-content\/uploads\/2021\/12\/Entwicklung-300x184.jpg 300w, https:\/\/ski-consult.de\/wp-content\/uploads\/2021\/12\/Entwicklung-768x471.jpg 768w, https:\/\/ski-consult.de\/wp-content\/uploads\/2021\/12\/Entwicklung-18x12.jpg 18w, https:\/\/ski-consult.de\/wp-content\/uploads\/2021\/12\/Entwicklung.jpg 1082w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Entwicklung der Anlagengr\u00f6\u00dfe und Nennleistung<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-96746a6 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"96746a6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8cd6d54\" data-id=\"8cd6d54\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c84d7a7 elementor-widget elementor-widget-text-editor\" data-id=\"c84d7a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"bodytext\">With increasing hub heights and plant sizes pushes the previous standard solution as a conical tubular steel tower is reaching its limits. The rapid growth of mass-produced wind turbines in terms of rated power, the rotor diameter and hub height can be seen in Figure 2.3. While the rotor diameter of a wind turbine in 1982 was D = 15 m, in 2008 are now systems with up to D = 125 m and 5 MW available. Prototypes with even greater benefits are currently being tested.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-81bd382 elementor-widget elementor-widget-text-editor\" data-id=\"81bd382\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Led as higher production and transportation costs for the tower diameter is greater than 4.3 m to alternative solutions, such as the reinforced concrete tower, which is produced on site with a climbing formwork. Alternatively, a few years since precast concrete towers for large hub heights, the lowest tower segments are transported upright and as part of shells to the site.\u00a0<\/p><p>If above concrete tower sections or steel tower sections are used, then one of these combined design variant to the category of hybrid towers.<\/p><p>To future larger plant types continue to run starting with steel supporting structures of the base of the tower, the\u00a0<a title=\"damage accumulation hypothesis\" href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/sandwichturm\/\">Sandwich tower<\/a>\u00a0has been developed to increase the shell stability and load-bearing capacity. The transport problem for diameters larger than 4.3 m is to be solved by a novel manufacturing concept.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-bec2001 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"bec2001\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-84db8c7\" data-id=\"84db8c7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-aeef144 elementor-widget elementor-widget-heading\" data-id=\"aeef144\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Services<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70e45f0 elementor-widget elementor-widget-text-editor\" data-id=\"70e45f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"main-content\"><div class=\"content\"><div id=\"c881\" class=\"csc-default\"><div class=\"csc-textpic-text\"><div class=\"content\"><div id=\"c361\" class=\"csc-default\"><div class=\"csc-textpic-text\"><p class=\"bodytext\">SKI Ingenieurges. mbH accompanies these onshore developments with<\/p><ul><li>Design and dimensioning of supporting structures<\/li><li>Calculation of wind loads in combination with other actions<\/li><li>Spannungs- und Stabilit\u00e4tsnachweise f\u00fcr &#8220;Primary and Secondary Steel&#8221;<\/li><li>Checks in the fatigue limit state<\/li><li>Development work in connection with new types of support structures<\/li><li><a class=\"internal-link\" title=\"damage accumulation hypothesis\" href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/strukturanalysen\/verbindungstechnik\/ringflanschverbindungen\/\">Fatigue proof for tubular joints and ring flange<\/a><\/li><li><a class=\"internal-link\" title=\"damage accumulation hypothesis\" href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/offshore-windenergieanlagen\/\">Concept studies for novel foundation structures of offshore wind turbines <\/a><\/li><li>Static-constructive assistance in certification\u00a0<\/li><li>Concept for observation method according to BSH standard<\/li><\/ul><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Trag- und Gr\u00fcndungsstrukturen f\u00fcr WEA Die\u00a0SKI\u00a0Ingenieurgesellschaft besch\u00e4ftigt sich mit Trag- und Gr\u00fcndungsstrukturen f\u00fcr Onshore-Windenergieanlagen.\u00a0Die Offshore-Varianten sind unter der separaten Rubrik\u00a0Offshore-Windenergieanlagen\u00a0zu finden. WEA-Stahlrohrturm Hybridturm &#8211; Betonschaft \/ Stahlrohrsektion Hybridturm &#8211; Gittermast \/ Stahlrohrsektion Abgespannte WEA mit Stahlrohrsektionen Tilt-Up Tower WEA &#8211; Gittermast Das Leistungsspektrum umfasst statische und dynamische Strukturanlaysen mit Hilfe von numerischen Simulationstools f\u00fcr die&#8230;<\/p>","protected":false},"author":4,"featured_media":0,"parent":7525,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-6049","page","type-page","status-publish","hentry","no-post-thumbnail"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Onshore-Windenergie &#8226; SKI Ingenieurges. mbH<\/title>\n<meta name=\"description\" content=\"Onshore-Windenergie &#8226; SKI kann Berechnungen inkl. Lastermittlung, Modellaufbau und Bewertung der Ergebnisse durchf\u00fchren.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Onshore-Windenergie &#8226; SKI Ingenieurges. mbH\" \/>\n<meta property=\"og:description\" content=\"Onshore-Windenergie &#8226; SKI kann Berechnungen inkl. Lastermittlung, Modellaufbau und Bewertung der Ergebnisse durchf\u00fchren.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/\" \/>\n<meta property=\"og:site_name\" content=\"SKI Ingenieurges. mbH\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-16T14:15:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ski-consult.de\/wp-content\/uploads\/2023\/11\/AN-WEA-Stahlrohrturm.gif\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ski-consult.de\\\/taetigkeitsbreiche\\\/onshore-windenergieanlagen\\\/\",\"url\":\"https:\\\/\\\/ski-consult.de\\\/taetigkeitsbreiche\\\/onshore-windenergieanlagen\\\/\",\"name\":\"Onshore-Windenergie &#8226; SKI Ingenieurges. mbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ski-consult.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ski-consult.de\\\/taetigkeitsbreiche\\\/onshore-windenergieanlagen\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ski-consult.de\\\/taetigkeitsbreiche\\\/onshore-windenergieanlagen\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ski-consult.de\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/AN-WEA-Stahlrohrturm.gif\",\"datePublished\":\"2020-07-30T14:55:54+00:00\",\"dateModified\":\"2023-11-16T14:15:43+00:00\",\"description\":\"Onshore-Windenergie &#8226; SKI kann Berechnungen inkl. Lastermittlung, Modellaufbau und Bewertung der Ergebnisse durchf\u00fchren.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ski-consult.de\\\/taetigkeitsbreiche\\\/onshore-windenergieanlagen\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ski-consult.de\\\/taetigkeitsbreiche\\\/onshore-windenergieanlagen\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/ski-consult.de\\\/taetigkeitsbreiche\\\/onshore-windenergieanlagen\\\/#primaryimage\",\"url\":\"https:\\\/\\\/ski-consult.de\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/AN-WEA-Stahlrohrturm.gif\",\"contentUrl\":\"https:\\\/\\\/ski-consult.de\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/AN-WEA-Stahlrohrturm.gif\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ski-consult.de\\\/taetigkeitsbreiche\\\/onshore-windenergieanlagen\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/ski-consult.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"T\u00e4tigkeitsbereiche\",\"item\":\"https:\\\/\\\/ski-consult.de\\\/taetigkeitsbreiche\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Onshore-Windenergie\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ski-consult.de\\\/#website\",\"url\":\"https:\\\/\\\/ski-consult.de\\\/\",\"name\":\"SKI Ingenieurges. mbH\",\"description\":\"Bauwesen und innovative Entwicklungsarbeiten\",\"publisher\":{\"@id\":\"https:\\\/\\\/ski-consult.de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ski-consult.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/ski-consult.de\\\/#organization\",\"name\":\"SKI Ingenieurges. mbh\",\"url\":\"https:\\\/\\\/ski-consult.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/ski-consult.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/ski-consult.de\\\/wp-content\\\/uploads\\\/2020\\\/07\\\/SKI_Logo_1026px_72dpi_rgb.png\",\"contentUrl\":\"https:\\\/\\\/ski-consult.de\\\/wp-content\\\/uploads\\\/2020\\\/07\\\/SKI_Logo_1026px_72dpi_rgb.png\",\"width\":1026,\"height\":373,\"caption\":\"SKI Ingenieurges. mbh\"},\"image\":{\"@id\":\"https:\\\/\\\/ski-consult.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Onshore-Windenergie &#8226; SKI Ingenieurges. mbH","description":"Onshore-Windenergie &#8226; SKI kann Berechnungen inkl. Lastermittlung, Modellaufbau und Bewertung der Ergebnisse durchf\u00fchren.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/","og_locale":"en_GB","og_type":"article","og_title":"Onshore-Windenergie &#8226; SKI Ingenieurges. mbH","og_description":"Onshore-Windenergie &#8226; SKI kann Berechnungen inkl. Lastermittlung, Modellaufbau und Bewertung der Ergebnisse durchf\u00fchren.","og_url":"https:\/\/ski-consult.de\/en\/taetigkeitsbreiche\/onshore-windenergieanlagen\/","og_site_name":"SKI Ingenieurges. mbH","article_modified_time":"2023-11-16T14:15:43+00:00","og_image":[{"url":"https:\/\/ski-consult.de\/wp-content\/uploads\/2023\/11\/AN-WEA-Stahlrohrturm.gif","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ski-consult.de\/taetigkeitsbreiche\/onshore-windenergieanlagen\/","url":"https:\/\/ski-consult.de\/taetigkeitsbreiche\/onshore-windenergieanlagen\/","name":"Onshore-Windenergie &#8226; SKI Ingenieurges. mbH","isPartOf":{"@id":"https:\/\/ski-consult.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ski-consult.de\/taetigkeitsbreiche\/onshore-windenergieanlagen\/#primaryimage"},"image":{"@id":"https:\/\/ski-consult.de\/taetigkeitsbreiche\/onshore-windenergieanlagen\/#primaryimage"},"thumbnailUrl":"https:\/\/ski-consult.de\/wp-content\/uploads\/2023\/11\/AN-WEA-Stahlrohrturm.gif","datePublished":"2020-07-30T14:55:54+00:00","dateModified":"2023-11-16T14:15:43+00:00","description":"Onshore-Windenergie &#8226; SKI kann Berechnungen inkl. Lastermittlung, Modellaufbau und Bewertung der Ergebnisse durchf\u00fchren.","breadcrumb":{"@id":"https:\/\/ski-consult.de\/taetigkeitsbreiche\/onshore-windenergieanlagen\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ski-consult.de\/taetigkeitsbreiche\/onshore-windenergieanlagen\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/ski-consult.de\/taetigkeitsbreiche\/onshore-windenergieanlagen\/#primaryimage","url":"https:\/\/ski-consult.de\/wp-content\/uploads\/2023\/11\/AN-WEA-Stahlrohrturm.gif","contentUrl":"https:\/\/ski-consult.de\/wp-content\/uploads\/2023\/11\/AN-WEA-Stahlrohrturm.gif"},{"@type":"BreadcrumbList","@id":"https:\/\/ski-consult.de\/taetigkeitsbreiche\/onshore-windenergieanlagen\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/ski-consult.de\/"},{"@type":"ListItem","position":2,"name":"T\u00e4tigkeitsbereiche","item":"https:\/\/ski-consult.de\/taetigkeitsbreiche\/"},{"@type":"ListItem","position":3,"name":"Onshore-Windenergie"}]},{"@type":"WebSite","@id":"https:\/\/ski-consult.de\/#website","url":"https:\/\/ski-consult.de\/","name":"SKI Ingenieurges. mbH","description":"Bauwesen und innovative Entwicklungsarbeiten","publisher":{"@id":"https:\/\/ski-consult.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ski-consult.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/ski-consult.de\/#organization","name":"SKI Ingenieurges. mbh","url":"https:\/\/ski-consult.de\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/ski-consult.de\/#\/schema\/logo\/image\/","url":"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/07\/SKI_Logo_1026px_72dpi_rgb.png","contentUrl":"https:\/\/ski-consult.de\/wp-content\/uploads\/2020\/07\/SKI_Logo_1026px_72dpi_rgb.png","width":1026,"height":373,"caption":"SKI Ingenieurges. mbh"},"image":{"@id":"https:\/\/ski-consult.de\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/ski-consult.de\/en\/wp-json\/wp\/v2\/pages\/6049","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ski-consult.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ski-consult.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ski-consult.de\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/ski-consult.de\/en\/wp-json\/wp\/v2\/comments?post=6049"}],"version-history":[{"count":0,"href":"https:\/\/ski-consult.de\/en\/wp-json\/wp\/v2\/pages\/6049\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/ski-consult.de\/en\/wp-json\/wp\/v2\/pages\/7525"}],"wp:attachment":[{"href":"https:\/\/ski-consult.de\/en\/wp-json\/wp\/v2\/media?parent=6049"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}